Inside the Motor

Construction, waveforms and DC alternatives for sewing-machine drives. A companion to Speed Control of Universal Motors in Sewing Machines

Claude (Anthropic), at the direction of Robert Drzyzgula

Development Build v82, November 2026

1 Summary

About this paper. The text, analysis, figures and simulations were written by Claude, an AI model made by Anthropic, at the direction of Robert Drzyzgula, who set its scope and questions. It is a companion to Speed Control of Universal Motors in Sewing Machines (cited here as “the speed-control paper”), which covers the physics of the series motor and each method of controlling it. This paper looks inside the motors themselves. The sources are listed in the last section; please report errors as issues on the project’s GitHub repository.

What it covers. The speed-control paper treats the sewing-machine motor as three letters in an equation: a resistance RR, a motor constant KK, and a speed ω\omega. This paper starts from the metal and copper.

The short answers.

  1. The universal motor is a DC series motor built to survive AC. Its iron is laminated, its brushes are high-resistance carbon, and its field and armature share one current. That shared current is why it runs on AC at all. It is also why its speed sags under load and why its back-EMF vanishes whenever the current stops.
  2. The inductance is mostly in the field coils, and it matters. It makes the current lag the line by about 30° at full speed. Behind a triac, it carries the current past the point where the line voltage reverses. It also turns each chopped slice of voltage into a smooth hump of current. At speed the back-EMF acts like extra resistance and shortens that smoothing. At a crawl the back-EMF is gone, so the smoothing lasts longer but the torque pulses grow sharper.
  3. Permanent-magnet and brushless motors behave like voltage-controlled speed sources. Their flux is fixed by magnets, so speed follows voltage and torque follows current, each on its own. That makes them far easier to regulate, to hold still, and to brake. They need DC and, in the brushless case, an electronic commutator.
  4. The induction motor needs no commutator at all. A three-phase supply makes a field that rotates by itself, and the rotor’s bars have their currents induced by the field sweeping past. It runs at nearly fixed speed off the line, a few percent below the field, and only a variable-frequency drive changes that. The sewing trade’s clutch motor was an induction motor with the speed control in a slipping clutch.
  5. Suitable DC motors exist, and they are small and cheap. Common 24 V brushed motors of the “775” size (42 mm across) deliver 60 W or more near 7,000 rpm. Brushless motors of 42–57 mm deliver 50–100 W at 3,000–4,000 rpm. Both fit easily within the envelope of a Singer external motor. Driving one would change the controller’s power stage completely: The RP2350B, its encoder and its firmware structure would carry over. Such a controller could do what a triac never can: brake actively and hold the needle exactly where it is put.

On the simulations. The waveforms here are computed from simple lumped models with representative values for a 99-class motor, not measured. They show the shapes and the cause and effect correctly. The exact numbers belong to the motor test rig, which is designed to measure RR, LL and KK and to put these waveforms on a scope. Its captures should replace these figures.

2 The universal motor, in iron and copper

2.1 What is inside

A sewing machine’s motor, a Singer BZ or BR, or one of the generic replacements sold for them, is a small two-pole universal motor. Taken apart, it has four groups of parts.

A two-pole universal motor, drawn schematically (not to scale): an end view through the armature. The two field coils are wound on the stator’s poles, and their flux crosses the armature from pole to pole and returns around the yoke. The armature conductors carry current one way on the left of the brush axis and the other way on the right (dots and crosses), which is what makes torque.
The same motor in a side view, in section: the laminated armature and the end turns of its winding, the field iron with its coils, the commutator, two carbon brushes on springs, the fan, the bearings and the pulley.

The stator (field).

The armature (rotor).

The commutator and brushes.

The commutator is a rotary switch. As the armature turns, it keeps reversing the current in each coil just as that coil passes from under one pole to under the other. The current pattern in the armature therefore stays fixed in space, flowing one way on one side of the brush axis and the other way on the other side, while the copper moves through it. Each conductor in the field feels a force, and every force pushes the same way around the shaft.

Everything else.

2.2 How the parts make up the equation

The speed-control paper’s model is

v=Ri+Ldidt+Kωi,T=Ki2,v = R\,i + L\frac{di}{dt} + K\,\omega\,i, \qquad T = K\,i^2,

and each term has a physical home in the motor.

The series connection and the lumped model it reduces to. One current passes through both field coils and the armature, so the field’s strength is set by the same current the armature carries. Below, the three terms of the model: the copper’s resistance, the inductance (mostly the iron-cored field coils), and the back-EMF.

2.3 One constant here, two later

Every brushed motor obeys the same two laws, whatever makes its field.

Here Φ\Phi is the field’s flux, ii the armature current, and kk a number fixed by how the armature is wound. The same kΦk\Phi appears in both, because they are two views of one exchange of energy. The electrical power the back-EMF absorbs, eie\,i, is the mechanical power the shaft delivers, TωT\omega. Both come to kΦωik\Phi\,\omega\,i.

Motors with a fixed field, shunt-wound (§4) and permanent-magnet (§5), have a constant Φ\Phi. Their kΦk\Phi is then one fixed number, and it is written twice, by the job it is doing:

In SI units the two are the same number. Datasheets often quote them in different units, such as volts per 1,000 rpm and ounce-inches per ampere, which hides that they are equal.

A series motor has no fixed field. Its flux is made by the armature current itself, so kΦk\Phi is proportional to ii. Writing kΦ=Kik\Phi = K\,i gives the paper’s model:

So the single KK used through §2 and §3 is not a third kind of constant. KiK\,i is the series motor’s KeK_e and KtK_t at once, a value that rises and falls with the current. KK itself has units of volts per (ampere × rad/s), which reduce to henries. The representative motor’s KK is 0.1037 H. At its running current of about 1 A, that makes an effective Ke=Kt≈0.10K_e = K_t \approx 0.10 V per rad/s (or N·m per ampere), comparable to a fixed-field motor’s constant. From §4 on, the motors have fixed fields, and the paper uses KeK_e and KtK_t.

2.4 Why it runs slower on AC than on DC

On DC, only RR and the back-EMF oppose the supply. On AC the inductance adds a reactance X=2πfLX = 2\pi f L, which is about 57 Ω at 60 Hz for the representative 0.15 H used in this paper. It uses up part of the supply voltage without doing work. A universal motor therefore runs noticeably faster on DC of the same voltage than on AC (Electrical Easy). This is also why a DC drive such as the KBIC, which rectifies the line, drives a universal motor as a DC series motor (speed-control paper, §8).

2.5 What the nameplates say

Sewing-motor nameplates are approximate, but they agree on the scale:

The motor on the bench here draws about 1.3 A (speed-control paper, §11). The representative motor used in the simulations below runs at about 7,000 rpm and draws 1.0 A from 120 V, and it delivers a mean torque of about 0.10 N·m, about 76 W.

3 The universal motor on the wire

This section shows what a scope would see at the motor’s terminals, and in its current, under each kind of control. The plots are computed with the model of §2, using the representative values listed with the figures: RR = 30 Ω, LL = 0.15 H, KK = 0.104 H, and a load that rises with speed. They come from tools/make_motor_waveforms.py. On the test rig, the same traces are taken with the scope behind an isolation transformer, voltage across the motor’s terminals and current across a small shunt (rig guide, §7).

3.1 Straight on the line

Simulated: the motor connected straight to 120 V, 60 Hz. The current (blue) is nearly a sine wave and lags the voltage (orange) by about 1.3 ms, or 28°. Below, the torque K i^2: always positive, pulsing at 120 Hz between zero and twice its mean.

Three things show here:

3.2 Behind a rheostat or carbon pile

Simulated: a 65 Ω rheostat in series, chosen to bring the motor down to the same speed as the 90° triac below (about 3,950 rpm). The motor sees a smaller sine, and the pedal turns about 42 W into heat.

A series resistance leaves every waveform a sine; it only makes them smaller. The motor sees a reduced sinusoidal voltage, and the current lags it a little less, because the circuit is now more resistive. What the scope does not show is the cost. At this setting the pedal dissipates about 42 W as heat in the foot control, more than the 28 W or so that the motor delivers. That is the heat the speed-control paper describes in §3. It also explains the carbon pile in that paper’s §11, which grew hot when held just short of starting. With the motor stalled there is no back-EMF, so most of the power goes into the pile.

3.3 Chopped by a triac

Simulated: a triac fired 45°, 90° and 120° into each half-cycle. The gray trace is the line, the orange trace the voltage at the motor, and the blue trace the motor current. In the middle panel, the dashed line shows what a plain resistor’s current would look like: a slice of sine that stops dead at the voltage zero.

How a triac switches. (The companion paper Inside a Switching Circuit covers the devices themselves.) A triac is a pair of thyristors (SCRs) back to back in one package, so it conducts in either direction. Its gate can turn it on but cannot turn it off. A short pulse of gate current starts it conducting. Once the load current has passed the triac’s latching current, it holds itself on and the gate has no further say. It turns off only when the current through it falls below its holding current, a few milliamps. In practice that means when the load current crosses zero, and then it waits for the next gate pulse. So the only control a triac offers is when to switch on in each half-cycle. This is leading-edge (forward-phase) control:

The other scheme, trailing-edge (reverse-phase) control, switches on at the zero and cuts off part-way through. It needs a switch that its gate can turn off, a MOSFET or an IGBT, and it is what some dimmers for LED lamps use. It suits a motor badly: cutting the current off sharply in an inductive load makes the inductance answer with a voltage spike (v=Ldi/dtv = L\,di/dt). This is why dimmers sold for motors and transformers are leading-edge.

The triac switches the full line on at the firing angle and leaves it on until the current falls to zero. The plots show what the inductance does with that.

Two practical consequences for the MCU controller:

What else the scope shows. The model leaves out two effects that a real trace has:

4 Wound-field DC motors: the universal motor’s relatives

A universal motor is one member of a family. Every brushed motor with a wound field is built from the same parts: field iron and coils, a slotted armature, a commutator and brushes. They differ in how the field coil is connected to the armature, and that one choice sets the speed–torque character. Before permanent magnets became strong and cheap, these were the DC motors, and they still drive treadmills, cranes and machine tools.

Speed control. For a shunt or separately excited motor, the controller sets the armature voltage. Industrial drives do this with a controlled rectifier, SCRs fired in phase like a triac but feeding a DC motor through a bridge. That is the KBIC’s circuit (speed-control paper, §8). Because the flux is constant, the armature voltage minus its IRIR drop is a direct measure of speed. That is why “IR compensation” regulates a shunt motor well, and a series motor only to a first approximation.

On the wire. A DC motor on a controlled rectifier sees the rectified line’s humps, with chopped leading edges. Its armature and field inductance smooth the current much as they do for the universal motor on the triac (§3). With enough inductance, the current flows continuously from one hump to the next instead of in pulses.

Why none of this is in a sewing machine.

Permanent magnets now give the shunt motor’s constant flux with no field winding at all, and that is the next section.

Speed against load torque, normalized to full speed at full load, at 100%, 70% and 40% of full voltage. Left: a series (universal) motor, whose speed collapses as load rises and soars as it falls. Right: a constant-flux motor, permanent-magnet or shunt, whose speed is set by its voltage and falls only slightly with load. Illustrative, from the two motors’ ideal equations.

5 Brushed permanent-magnet DC motors

5.1 Construction

A brushed permanent-magnet (PM) motor is a shunt motor whose field coils have been replaced by magnets.

The common “775” motor, sold for drills, pumps and robots, is a good example. It is a 42 mm can, 66.5 mm long, with a 5 mm shaft.

A brushed permanent-magnet motor, schematically. The magnets set the flux, which crosses the armature exactly as in the universal motor, but the armature current no longer makes it. The lumped model has the same three terms, with a back-EMF that depends on speed alone.

5.2 What the equations say

With the flux fixed,

v=Ri+Ldidt+Keω,T=Kti,v = R\,i + L\frac{di}{dt} + K_e\,\omega, \qquad T = K_t\,i,

and in SI units Kt=KeK_t = K_e (N·m per ampere equals volts per rad/s). Three consequences matter for a sewing machine:

They also run backward when the supply is reversed, and they act as generators when driven, which is the basis of braking.

5.3 Speed control: the chopper and the H-bridge

A PM motor needs DC, and its speed is set by the average voltage across it. A controller makes that average by pulse-width modulation (PWM): it switches the full supply on and off many thousands of times a second, and the share of time it is on, the duty cycle, sets the average.

Outline drive circuits. Left: a triac in series with a universal motor on the mains. Center: a chopper for a PM motor, with one switch and a freewheeling diode, for one direction. Right: an H-bridge, with four switches for forward, reverse and braking.

5.4 On the wire

Simulated: a 24 V, 775-size motor (R = 0.98 Ω, an assumed L = 0.2 mH) on a chopper at 50% duty, turning at about 3,500 rpm. At 2 kHz (left) the switch period is longer than the motor’s 0.2 ms electrical time constant. The current rises steeply, then falls to zero partway through each off-time, and the terminals show the back-EMF (the 10 V steps) until the next pulse. At 20 kHz (right) the current only ripples by about 1.6 A around its mean.

The voltage at the motor is a square wave between the supply and slightly below zero (the diode’s drop). The current is what the inductance makes of it.

Hearing it: the cordless drill. A cordless drill whose trigger is held just short of turning the chuck often lets out a high-pitched whine. That whine is the switching frequency.

The tone can be measured. A spectrum-analyzer app on a phone, held near the tool, shows a sharp peak at the switching frequency. There are two cautions:

The certain answer is a scope across the motor’s leads, which shows the frequency and the duty cycle at once, at a battery voltage that is safe to probe.

Measured: a drill and an impact driver. Two DeWalt 20 V Max tools were measured this way in a quiet room, with a phone’s microphone and a spectrum-analyzer app:

Both are brushed models: replacement carbon brushes are sold for both (iFixit, vhbw). Each is a PM motor on a single PWM switch, the circuit of this section. Each tool was recorded three times: the room alone, the trigger just in, and the trigger fully in.

Measured: sound spectra of a DeWalt DCD780 drill (top) and DCF885 impact driver (bottom), from an iPhone running an FFT analyzer app, each with the room alone (gray), the trigger just in (blue) and the trigger fully in (orange). The dotted lines mark the narrow lines described in the text. Read back from the app’s screenshots and replotted.

A faint third harmonic has a likely cause. A train of pulses at duty cycle DD has harmonics whose sizes go as |sin(nπD)|/n|\sin(n\pi D)|/n. At DD near 1/3, the third falls to nothing while the second and fourth stay strong. The motor’s mechanical response and the phone’s microphone shape the levels too, so this is a likely cause, not a proof.

What it means for control. A PM motor drive usually has two loops:

A third, position loop can sit outside both. This is how industrial servo drives are built, and an RP2350 can run all three.

6 Brushless DC motors

6.1 Construction

Turn the PM motor inside out:

The stator is wound as three phases, usually connected in a star.

Left: a brushless inrunner, schematically. Six stator teeth are wound as three phases (A, B, C, each on two opposite teeth), with a four-pole magnet rotor inside. Three Hall sensors report the rotor’s position. Right: the three-phase bridge that drives it, six switches, one pair per phase.

Two arrangements are common:

Poles and Hall sensors. Motors usually have 4–14 magnet poles. With pp pole pairs, the current pattern must go round its cycle pp times per mechanical revolution. Three Hall-effect sensors, set 120 electrical degrees apart, divide each electrical cycle into six states, so an 8-pole motor (4 pole pairs) reports 24 distinct positions per turn. That point returns in §9.

The ratings. Brushless motors are rated by:

6.2 Driving it

A brushless motor cannot run without its controller. Connect it to a supply and it sits still. The controller’s three-phase bridge does the commutator’s work, in one of two ways.

Idealized six-step drive. Top three rows: each phase’s back-EMF (trapezoidal, flat for 120°) and the current block the driver applies while that phase’s back-EMF is flat. Fourth row: the three Hall signals, whose edges fall at the commutation points. Bottom: which two phases carry current in each 60° step.

On the wire. In six-step drive:

Under FOC the currents become clean sines with a little PWM ripple.

What it gives a sewing machine. It gives everything the PM motor does:

On top of that it gives:

Brushless servo motors replaced the clutch motor (§7) on industrial sewing machines for these reasons. They are typically a few hundred watts, mounted under the table, with the controller in the same housing (Leather Machine Co.).

7 Induction motors: AC with nothing to wear

The motors so far all have something that switches the current to keep the torque going one way: a commutator and brushes, or transistors. The induction motor has neither. It is the motor of fans, pumps, compressors, table saws and almost every factory floor, and on the sewing floor it was the clutch motor that the brushless servo replaced (§6).

7.1 Construction

The rotor has no magnets, no brushes, no commutator and no electrical connection of any kind. Its only wearing parts are its two bearings.

7.2 The rotating field

Three windings set 120° apart around the stator, carrying three currents 120° apart in time, make a field of constant strength that turns. Nothing moves to make it rotate. The rotation comes from the supply itself, as each phase’s current peaks in turn. The field turns at the synchronous speed

ns=120fprpm,n_s = \frac{120 f}{p} \ \text{rpm},

with ff the supply frequency and pp the number of poles. On 60 Hz a two-pole motor’s field turns at 3,600 rpm, a four-pole motor’s at 1,800, and a six-pole motor’s at 1,200.

This is what a brushless controller does with its six transistors (§6): it makes a rotating field. The difference is that the brushless controller times the field to the rotor’s position, which it reads from Hall sensors. The induction motor’s field just turns at line frequency, and the rotor follows as best it can.

7.3 Slip and torque

If the rotor turned at the synchronous speed, the field would stand still relative to the bars, nothing would be induced in them, and there would be no torque. So the rotor always runs a little slower than the field. The difference is the slip:

s=ns−nns.s = \frac{n_s - n}{n_s}.

The field sweeps past the bars at the slip speed. That induces currents in them, the shorting rings let those currents flow, and the currents in the field make torque. A larger load slows the rotor a little more, which raises the slip, the induced current and the torque, until the torque matches the load. At full load the slip is typically 2–5%, which is why a four-pole motor’s nameplate says about 1,725 rpm, not 1,800.

A representative four-pole induction motor (computed with the Kloss approximation: breakdown torque 2.8 times full load, at 20% slip). On the 60 Hz line (black) it starts with about full-load torque, rises to its breakdown torque, and settles on the steep upper part of the curve, where speed barely changes with load. On a VFD (gray), the same curve slides down with the synchronous speed.

The curve has three landmarks:

7.4 Single-phase motors

A single winding on single-phase AC makes a field that pulses back and forth but does not rotate. Such a motor, once turning, keeps turning in either direction, but it has no starting torque at all. The cure is a second, auxiliary winding, set 90° around the stator from the main one, with its current shifted in time:

7.5 The clutch motor

The induction motor’s fixed speed is its strength in a factory and its weakness at a sewing machine. The industrial clutch motor works around it mechanically:

The motor hums and draws power all day, sewing or not. The brushless servo that replaced it (§6) is quiet, off between seams, holds a set speed, and can stop with the needle up or down. The clutch motor’s speed control was in the operator’s foot and in the cork, never in the motor.

7.6 Speed control: the variable-frequency drive

Since the speed follows the supply’s frequency, the way to change the speed is to change the frequency. That is what a variable-frequency drive (VFD) does:

  1. A rectifier turns the mains into DC.
  2. A DC bus, a bank of capacitors, smooths it.
  3. A three-phase inverter, six transistors on PWM (2–16 kHz), turns the DC back into three-phase AC at whatever frequency is wanted.

The inverter is the same three-phase bridge that drives a brushless motor (§6). The difference is in what times it. A brushless controller follows the rotor’s position. A plain VFD just generates the frequency it is told to.

Why it is not the answer for the VSM Base. An induction motor of a sewing motor’s power would be larger and heavier than the brushless motors of §9 for the same output, and needs its VFD for any speed control. A three-phase motor needs a three-phase drive. The drives sold for single-phase motors are few, and a capacitor-start motor, with its centrifugal switch, does not work on one at all. The brushless motor does the same job, is smaller, and its controller already knows where the rotor is.

8 The five motors side by side

Universal (series) Wound-field DC (shunt) Brushed PM DC Brushless DC Induction (squirrel cage)
Field made by the load current a separate field winding magnets on the stator magnets on the rotor the stator winding; rotor currents induced
Commutation commutator and brushes commutator and brushes commutator and brushes transistors, from Hall sensors or an encoder none: the supply rotates the field
Runs on AC or DC, straight off the line DC (rectified mains) DC only DC, through its controller only AC, straight off the line; single-phase needs a start winding
Torque Ki2K i^2: high at a stall KtiaK_t i_a KtiK_t i KtiK_t i rises with slip; moderate at a stall
Speed with load falls steeply; races unloaded nearly constant nearly constant nearly constant nearly constant (a few % slip)
Speed control voltage: rheostat, triac, variac armature voltage (SCR drive), field weakening PWM chopper or H-bridge PWM on a three-phase bridge frequency: a VFD
Speed feedback needs a sensor; back-EMF only while current flows armature voltage minus IRIR back-EMF read directly Hall sensors or encoder, built in none needed on the line; an encoder for vector control
Braking, holding coasts; cannot hold dynamic braking dynamic braking; holds with current dynamic braking; holds with current braking through a VFD; holds only with vector control
Wear brushes, commutator brushes, commutator brushes, commutator bearings only bearings only
Electrical noise brush sparking brush sparking brush sparking, PWM PWM none on the line; PWM on a VFD
Without electronics works (with a pedal) works on DC works on DC (no speed control) does not run works, at one speed

Read across, the table says why the universal motor won the sewing machine and why it is no longer the obvious choice.

9 Could a DC motor drive a vintage machine?

9.1 What the job asks for

The universal motors that drive these machines set the target (§2):

The space. A Singer external motor’s body, as measured for the test rig’s cradle, is about 51 × 64 mm in section and 114 mm long. It hangs from a bracket on the back of the machine and drives the hand wheel through a belt.

Speed itself is negotiable: the belt’s ratio sets it. A motor with twice the torque at half the speed, given a motor pulley twice the size, turns the hand wheel just as well. Power is what has to match.

9.2 Candidates

All of these run on 24 V DC. The first three fit well inside the Singer motor’s envelope. The 57 mm brushless motor fits its length and its 64 mm side, but is a little wider than its 51 mm side. Specifications are as published by the sellers cited. Ratings for generic motors vary between sellers and should be checked on the bench.

Motor Type Size Ratings at 24 V Approx. price
“775” brushed motor Brushed PM 42 mm dia. × 66.5 mm, 5 mm shaft 8,300 rpm no load; 0.082 N·m and 3.5 A at 7,354 rpm (about 63 W); 0.72 N·m at a stall (RobotShop) $12
“50SRZ” brushed motor Brushed PM 50 mm dia. × about 100 mm, 6 mm shaft Sold in 2,000–8,000 rpm versions; power ratings vary by seller (eBay listing) $55
42BLS02 Brushless, 8 poles 42 mm square flange × 61 mm 4,000 rpm; 0.125 N·m and 3.3 A rated (52.5 W); 0.38 N·m peak (Robu) $25
57BLY100, with driver Brushless, 4 poles, Hall sensors 57 mm dia. × 87 mm, 8 mm shaft 3,000 rpm; 0.33 N·m and 5 A rated (103 W) (RobotShop) $77 with driver

There is also evidence from practice:

So the answer to the first question is yes. Small, cheap DC motors with a sewing motor’s power exist, and they fit its space. A brushed 775 at 24 V is the simplest candidate. A 42 mm or 57 mm brushless motor is the better one.

9.3 What the controller would become

The MCU controller in the speed-control paper is built around a triac because the motor runs on mains AC. A DC motor changes its power stage completely and leaves its brain much as it is. A concept schematic of the brushed version, a 775 on an off-the-shelf H-bridge, is in the speed-control paper’s §11 (“A DC-motor variant”) and in the repository at hardware/mcu-controller-dc/.

9.4 What it costs

9.5 Recommendation

A DC-motor variant of the controller is worth keeping open, in the same spirit as the parked ideas in the speed-control paper’s §11.

  1. Start on the bench, not in the machine.
  2. If that goes well, design a low-voltage power stage for the RP2350B board, H-bridge first, three-phase second. Keep the triac design for machines that keep their original motors.

The two would share their sensors, their pedals and most of their firmware.

10 Sources

  1. Universal Motor: construction, working and characteristics, Electrical Easy.
  2. Power of a motor, Vintage Sewing Machines blog, February 2020.
  3. Singer sewing machine motors, foot controllers and drive belts, singersewinginfo.co.uk.
  4. R. Scheibe, Janome 415 with DC motor.
  5. Motor drive for sewing machines, SimpleFOC Community forum.
  6. 775 DC Motor, 24 V 8300 RPM, RobotShop product page.
  7. 50SRZ 12 V/24 V DC motor, eBay listing.
  8. 42BLS02 24 V 4000 RPM brushless motor, Robu product page.
  9. 57 mm Brushless DC Motor with Driver Kit, 24 V 103 W, RobotShop product page.
  10. Brushless Digital D.C. Servo Motor, Leather Machine Co. product page.
  11. I. Skalka, Low-Cost Universal Motor Phase Angle Drive System, Freescale AN1662.
  12. New brushes for the DCF885, iFixit Answers.
  13. vhbw carbon brushes for the DeWalt DCD780 and DCD785, ManoMano product page.
  14. A. Hughes and B. Drury, Electric Motors and Drives: Fundamentals, Types and Applications, 5th ed., Newnes, 2019.
  15. A. E. Fitzgerald, C. Kingsley and S. D. Umans, Electric Machinery, 7th ed., McGraw-Hill, 2014.

The motor model, its equations and the speed-control methods are those of the companion paper, Speed Control of Universal Motors in Sewing Machines, and its sources. The simulations and drawings are generated by tools/make_motor_waveforms.py and tools/make_motor_drawings.py in the project repository. The cordless-tool spectra in §5 are Robert Drzyzgula’s measurements, phone screenshots kept in docs/images/motors/measured/, read back and replotted by tools/make_tool_spectra.py.

The construction and theory of the motors themselves, §2 and §4–§7, are standard textbook material, given here without citation line by line. Hughes and Drury is the readable practitioner’s account, drives included; Fitzgerald, Kingsley and Umans is the standard engineering text.